Solved problem after some effort |
January 28, 2020 |
Reviewer:
K. Jones
|
|
The draft fan & blower on the MHU45 garage heater turned on at the same time. The unit was out of cycle and would not ignite. Replacing the circuit board fixed the problem. However, the circuit board came with longer stand offs. The original shorter ones easily snapped in place and stayed on the board while securing the screws. Some of the new ones did not snap onto the board. Instead it came with new screws & washers. I was not able to keep them in place while attempting to attach the board. Also, the new screws were not long enough to screw the board in place with the new spacers.The solution was to remove the original spacers & attach them to the new board. Hopefully the longer ones were not important to the performance of the new board. Meanwhile, all is well again. Shipping & handling from TESS was excellent.
Was this review helpful to you?
|
|
|
|
|
|